Low-voltage current applied across waterproofing membranes to detect breaches. Electrical resistance paths reveal pinholes and defects in flat roofs and waterproofing.

Electronic leak detection is the most reliable method for locating breaches in flat roof membranes and below-grade waterproofing systems. A low-voltage DC current (typically 30-40 volts at micro-amp levels) is applied across the membrane using a conductive medium on the surface (water, conductive foam roller, or brush). The current flows through any breach in the membrane to the conductive substrate below, completing a circuit that the detection instrument identifies. The technician follows the current path to its source — the exact breach location. ELD can detect pinholes as small as 1 mm that would be invisible during visual inspection. This method is essential for quality assurance on new membrane installations and for troubleshooting chronic leaks in existing systems.

Our technicians are experienced in applying Electronic Leak Detection (ELD) in Richmond and across the Metro Vancouver region. We have the equipment, training, and local knowledge to deploy this method effectively for your specific situation.

Applications in Richmond

  • Flat roof membrane leak detection on commercial buildings
  • Green roof waterproofing integrity testing
  • Below-grade waterproofing membrane testing