Warm Spots on the Floor — Radiant Heat Leak Indicator
Back to all problems
Common Water Issue in BC

Warm Spots on the Floor — Radiant Heat Leak Indicator

Warm spots on concrete or tiled floors in a building with radiant heating may indicate a leak in the hydronic heating loop. The escaping hot water raises the floor temperature at the leak point before cooling and escaping.

Possible Causes

  • Radiant floor heating loop leak from pipe damage or installation defect
  • Pinched or kinked PEX tubing during construction or renovation
  • Concrete slab crack that has compromised an embedded heating pipe
  • Corrosion at connection fittings for radiant loop manifolds
  • Abrasion of pipe against concrete aggregate causing gradual wear

Recommended Steps

  • 1Note the location and size of warm spots — photograph for reference
  • 2Check boiler pressure gauge — dropping pressure indicates system water loss
  • 3Turn off the radiant system and monitor pressure for 24 hours
  • 4Call a leak detection specialist with thermal imaging for slab leak detection
  • 5Do not cut into slab until the exact leak point is identified